| /* |
| * 8253/8254 Programmable Interval Timer (PIT) emulation |
| * |
| * Copyright 2003 Jukka Heinonen |
| * |
| * This library is free software; you can redistribute it and/or |
| * modify it under the terms of the GNU Lesser General Public |
| * License as published by the Free Software Foundation; either |
| * version 2.1 of the License, or (at your option) any later version. |
| * |
| * This library is distributed in the hope that it will be useful, |
| * but WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
| * Lesser General Public License for more details. |
| * |
| * You should have received a copy of the GNU Lesser General Public |
| * License along with this library; if not, write to the Free Software |
| * Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301, USA |
| */ |
| |
| #include "config.h" |
| |
| #include "dosexe.h" |
| #include "wine/debug.h" |
| #include "wingdi.h" |
| #include "winuser.h" |
| |
| WINE_DEFAULT_DEBUG_CHANNEL(int); |
| |
| /* |
| * FIXME: Use QueryPerformanceCounter for |
| * more precise GetTimer implementation. |
| * FIXME: Use QueryPerformanceCounter (or GetTimer implementation) |
| * in timer tick routine to compensate for lost ticks. |
| * This should also make it possible to |
| * emulate really fast timers. |
| * FIXME: Support special timer modes in addition to periodic mode. |
| * FIXME: Use timeSetEvent, NtSetEvent or timer thread for more precise |
| * timing. |
| * FIXME: Move Win16 timer emulation code here. |
| */ |
| |
| /* The PC clocks ticks at 1193180 Hz. */ |
| #define TIMER_FREQ 1193180 |
| |
| /* How many timer IRQs can be pending at any time. */ |
| #define TIMER_MAX_PENDING 20 |
| |
| /* Unique system timer identifier. */ |
| static UINT_PTR TIMER_id = 0; |
| |
| /* Time when timer IRQ was last queued. */ |
| static DWORD TIMER_stamp = 0; |
| |
| /* Timer ticks between timer IRQs. */ |
| static UINT TIMER_ticks = 0; |
| |
| /* Number of pending timer IRQs. */ |
| static LONG TIMER_pending = 0; |
| |
| /* Number of milliseconds between IRQs. */ |
| static DWORD TIMER_millis = 0; |
| |
| /*********************************************************************** |
| * TIMER_Relay |
| * |
| * Decrement the number of pending IRQs after IRQ handler has been |
| * called. This function will be called even if application has its |
| * own IRQ handler that does not jump to builtin IRQ handler. |
| */ |
| static void TIMER_Relay( CONTEXT *context, void *data ) |
| { |
| InterlockedDecrement( &TIMER_pending ); |
| } |
| |
| |
| /*********************************************************************** |
| * TIMER_TimerProc |
| */ |
| static void CALLBACK TIMER_TimerProc( HWND hwnd, |
| UINT uMsg, |
| UINT_PTR idEvent, |
| DWORD dwTime ) |
| { |
| LONG pending = InterlockedIncrement( &TIMER_pending ); |
| DWORD delta = (dwTime >= TIMER_stamp) ? |
| (dwTime - TIMER_stamp) : (0xffffffff - (TIMER_stamp - dwTime)); |
| |
| if (pending >= TIMER_MAX_PENDING) |
| { |
| |
| if (delta >= 60000) |
| { |
| ERR( "DOS timer has been stuck for 60 seconds...\n" ); |
| TIMER_stamp = dwTime; |
| } |
| |
| InterlockedDecrement( &TIMER_pending ); |
| } |
| else |
| { |
| DWORD i; |
| |
| /* Calculate the number of valid timer interrupts we can generate */ |
| DWORD count = delta / TIMER_millis; |
| |
| /* Forward the timestamp with the time used */ |
| TIMER_stamp += (count * TIMER_millis); |
| |
| /* Generate interrupts */ |
| for(i=0;i<count;i++) |
| { |
| DOSVM_QueueEvent( 0, DOS_PRIORITY_REALTIME, TIMER_Relay, NULL ); |
| } |
| } |
| } |
| |
| |
| /*********************************************************************** |
| * TIMER_DoSetTimer |
| */ |
| static void WINAPI TIMER_DoSetTimer( ULONG_PTR arg ) |
| { |
| INT millis = MulDiv( arg, 1000, TIMER_FREQ ); |
| |
| /* sanity check - too fast timer */ |
| if (millis < 1) |
| millis = 1; |
| |
| TRACE_(int)( "setting timer tick delay to %d ms\n", millis ); |
| |
| if (TIMER_id) |
| KillTimer( NULL, TIMER_id ); |
| |
| TIMER_id = SetTimer( NULL, 0, millis, TIMER_TimerProc ); |
| TIMER_stamp = GetTickCount(); |
| TIMER_ticks = arg; |
| |
| /* Remember number of milliseconds to wait */ |
| TIMER_millis = millis; |
| } |
| |
| |
| /*********************************************************************** |
| * DOSVM_SetTimer |
| */ |
| void DOSVM_SetTimer( UINT ticks ) |
| { |
| /* PIT interprets zero as a maximum length delay. */ |
| if (ticks == 0) |
| ticks = 0x10000; |
| |
| if (!DOSVM_IsWin16()) |
| MZ_RunInThread( TIMER_DoSetTimer, ticks ); |
| } |
| |
| |
| /*********************************************************************** |
| * DOSVM_Int08Handler |
| * |
| * DOS interrupt 08h handler (IRQ0 - TIMER). |
| */ |
| void WINAPI DOSVM_Int08Handler( CONTEXT *context ) |
| { |
| BIOSDATA *bios_data = DOSVM_BiosData(); |
| CONTEXT nested_context = *context; |
| FARPROC16 int1c_proc = DOSVM_GetRMHandler( 0x1c ); |
| |
| nested_context.SegCs = SELECTOROF(int1c_proc); |
| nested_context.Eip = OFFSETOF(int1c_proc); |
| |
| /* |
| * Update BIOS ticks since midnight. |
| * |
| * FIXME: What to do when number of ticks exceeds ticks per day? |
| */ |
| bios_data->Ticks++; |
| |
| /* |
| * If IRQ is called from protected mode, convert |
| * context into VM86 context. Stack is invalidated so |
| * that DPMI_CallRMProc allocates a new stack. |
| */ |
| if (!ISV86(&nested_context)) |
| { |
| nested_context.EFlags |= V86_FLAG; |
| nested_context.SegSs = 0; |
| } |
| |
| /* |
| * Call interrupt 0x1c. |
| */ |
| DPMI_CallRMProc( &nested_context, NULL, 0, TRUE ); |
| |
| DOSVM_AcknowledgeIRQ( context ); |
| } |